From my understanding all splicing of electrical wiring has to be contained in a junction box.
Running wire in attic code.
Also it may not be as simple as stapling the wiring to the structural members.
If the attic is accessible by permanent stairs or ladder any cable running across the top of joists will have to be protected.
If the wires are within 7 of the attic access hole or along any attic flooring you ll need to protect the wiring from damage with furring strips along each side of the wire run.
My attic is non accessible so i know for a fact that i must protect the romex with guard strips or bore holes 1 25 from the face of the joists when running perpendicular to the joists and when i run parallel i must staple the romex to the face of the joists.
I was also under the impression that if wiring is in an attic space that it may need to be derated because it can get very hot up there.
An attic that is accessible which is defined by the nec as having a permanently installed stair or ladder in place must have protection for any cables that run across the top of the attic floor joists or within 7 feet where they run across the face of rafters or studs.
When romex is run across rafters in an open unfinished attic it is my position that a raceway of some kind 1x3 s or even 2x4 s should first be attached across the affected rafters perhaps 3 to 4 above the joists then the wiring be stapled to the raceway.
5 hollow spaces of walls ceilings and attics where such spaces are insulated by loose rolled or foamed inplace insulating material that envelops the conductors.
If this meets code then i will be running attic wiring in this manner from now on.
Methods of proper attic electrical wiring raul no this is not a standard practice and is most likely the result of improper installation of electrical attic wiring.
I cannot find this specifically in code so here is my question.
A pull down attic ladder does not count.
And use semi rigid wiring fish tape to pull your wiring down to your outlet location.
When cutting through drywall from the interior of a room use a utility knife and cut carefully you don t want to drill through a hidden wire or the paper backing of the attic insulation.
If you will need to fish wiring through a wall drill a hole through the wood plate in the attic only.
Concealed knob and tube wiring shall not be used in the following.
This will protect the wiring from being accidentally snagged.
I am trying to figure out the code violation of having spliced electrical wiring in an attic put together with wire nuts.
I did a lot of reading about it but am confused about the best way to do it.
Use a 2x4 as a running board and staple to the side of it.
Whenever i do attic wiring i remove the insulation and staple it to the ceiling joist.
Nec 2008 394 12 uses not permitted.
Installing additional electrical wiring should be done according to local and national electrical codes with a permit and be inspected.
There is exposed wiring and i have photos i can send.